Flash Point
Safety is one of the most important considerations when handling various petroleum products due to their chemical nature and tendancy towards flammability. As such, flash point testing is a critical property for lubricants, oils, fuels, and other chemicals.
Products
Automatic Flash Point
K71000 |
Automatic Pensky-Martens Flash Point TesterFor flash point determination of biodiesel, distillate fuels, new lubricating oils, residual fuel oils, cutback residual, used lubricating oils, mixtures of petroleum liquids with solids, and petroleum liquids that tend to form a surface film during testing. |
|
K72000 |
Automatic Cleveland Flash Point TesterFor flash and fire point of all petroleum products, except fuel oils and those having an open cup flash below 79°C (175°F). |
|
K24880 |
Automatic Microscale Continuously Closed Cup TesterFor determination of flash point of fuel oils, lube oils, solvents and other liquids by continuously closed cup tester. The measurement is made on a test specimen of 1 mL and utilizes a closed but unsealed cup with air injected into the test chamber. |
|
K87390 |
Automatic Abel Flash Point TesterFor flash point determination of petroleum products and other liquids having flash points between -30°C and 110°C. |
|
K23802
|
Automatic Tag Closed Cup Flash Point TesterFor the determination of the flash point of liquids with a viscosity below 5.5 mm2/s (cSt) at 40°C (104°F), or below 9.5 mm2/s (cSt) at 25°C (77°F), and a flash point below 93°C (200°F). |
|
Manual Flash Point
K16203
|
Pensky Martens Closed Cup Flash TesterFor flash point determinations of fuels, lubricating oils, liquids containing suspended solids and liquids that tend to form a surface film during testing. |
|
K13902
|
BVS5000 Brookfield Viscosity Air Bath SystemFor flash and fire points of all petroleum products, except fuel oils and those having an open cup flash point below 79°C (175°F). |
|
K17400
|
Abel Closed Cup Flash Point TesterFor the determination of the closed cup flash point of petroleum products and other liquids having flash points below -30°C and 70°C inclusive. |
|
K15601
|
Tag Open Cup Flash TesterFor determination of flash and fire points of liquids at temperatures of up to 325°F (163°C) and flash points of cutback asphalts at temperatures of less than 200°F (93°C). |
|
K14601
|
Tag Closed Cup Flash TesterFor flash point determinations of liquids with a viscosity of below 5.5 centistokes (cSt) at 104°F (40°C) or below 9.5cSt at 77°F (25°C), and a flash point below 200°F (93°C) except cut-back asphalts, those liquids which tend to form a surface film under test conditions and materials which contain suspended solids. |
|
K16503
|
Open Cup Rapid TesterVerifies the flash point or the sustained burning qualities of small samples in the range of –30°C to +300°C. |
|
K16500
|
Closed Cup Rapid TesterVerifies the flash point or the sustained burning qualities of small samples in the range of –30°C to +300°C. |
|