High and Low Temperature Viscosity Standards
- Manufactured and certified according to ASTM D2162, the primary method for viscosity reference standards
- Supplied with an ISO/IEC 17025 Certification Report
- Fully compliant to ASTM and related test procedures
- Custom standards available
Koehler viscosity reference standards are used for calibration and verification of kinematic and dynamic viscosity test equipment, both manual and automatic. All viscosity standards are based upon the National Institute of Standards and Technology (NIST) value of 1.0034 cSt (Centistokes) for water at 20°C (68°F). All standards are traceable to National Standards and are manufactured and certified according to ASTM D2162, the internationally recognized primary method for viscosity reference standards, under ISO/IEC17025 guidelines. Standards are calibrated to a precision of ±0.2% for the viscosity and kinematic viscosity. Nominal or approximate values are listed in the following tables. With each standard, actual certified values for kinematic viscosity (cSt), dynamic viscosity (cP), and density (g/mL) according to ASTMD1480 are provided at each temperature point of calibration along with uncertainty measurements. Each standard is calibrated at a minimum of five temperatures and supplied in a 500mL quantity in an amber-colored bottle complete with full certification and a Material Data Safety Sheet (MSDS).In addition to the many viscosity standards described in this catalog, we can supply custom viscosity standards made specifically to meet your individual needs including high volume supply used for Statistical Quality Check and Statistical Process Control (SQC/SPC) applications.
Important Information About Viscosity Standards
All Koehler certified viscosity standards are Newtonian fluids manufactured from high stability base oils and polybutenes. The standards have an expiration date on the label at least twelve months or longer from the date of purchase. With time, changes resulting from slow oxidation or loss of volatiles may occur. These changes can be minimized by storing the standard in the closed bottle at ambient laboratory temperatures and out of sunlight. The expiration date on the label is part of Koehler’s program of total quality control and is intended to ensure that the standard will be utilized while the certified viscosity data remains valid.
Low Viscosity Table
Catalog | Visc. | For Viscosities |
Number | Std. | in cP of |
355-005-105 | N105B | -25, -21, -20.5, -20, -19.5, -19°C |
355-005-115 | N115B | -20, -15, -10, 0, +10, 20°F |
355-005-120 | N120B | -41, -40.5, -40, -39.5, -39°C |
355-005-142 | N1400B | -13, -12.5, -12.22, -12, -11.5, -11°C |
355-005-141 | N14B | -40, -35, -30, -25°C |
355-005-027 | N27B | -40, -30, -20, -15, -10, 0°F |
355-005-002 | N2B | -20, 0°C |
355-005-400 | N400B | -26, -25.5, -25, -24.5, -24°C |
355-005-480 | N480B | -27, -26.5, -26.11, -26, -25.5, -25°C |
355-005-910 | J10 | -40°C |
355-005-911 | JF1-H | -40, -20°C |
355-005-912 | JF1-L | -40, -20°C |
High Viscosity Table
20°C | 25°C | 60°C | 60°C | 135°C | ||
Catalog | Visc. | 68°F | 77°F | 140°F | 140°F | 275°F |
Number | Std. | cP | cP | cP | cSt | cSt |
355-004-600 | N600 | — | 1400 | 140 | 160 | 12 |
355-004-103 | N1000 | — | 2000 | 280 | 350 | — |
355-004-203 | N2000 | — | 4900 | 380 | 440 | 26 |
355-004-403 | N4000 | — | 11000 | 730 | 850 | — |
355-004-803 | N8000 | — | 20000 | 1400 | 1600 | — |
355-004-153 | N15000 | — | 41000 | 2600 | 3000 | — |
355-004-304 | N30000 | 130000 | 80000 | 4700 | 5400 | — |
355-004-623 | N62000 | — | 200000 | 13000 | — | — |
355-004-154 | N150000 | — | 420000 | 24000 | — | — |
355-004-194 | N190000 | 900000 | 520000 | 33000 | — | — |
355-004-454 | N450000 | — | 1600000 | 100000 | — | — |
355-004-275 | N2700000 | — | 5300000 | 340000 | — | — |